Product banner-21

product

MC2/012-1HRF Car Relay for car fuse box

Description: MC2/012-1HRF 30A  Relay for Automotive Fuse Box

Series: Car Relay

Parts No. : MC2/012-1HRF

Contact Switching Capability : 30A

Insulation Resistance : 100M Ω (500VDC)


Reference No.: MC2/012-1HRF

Product Detail

About US

Product Tags

Basic Information

Parts No.:MC2/012-1HRF

Name:Car Relay

Contact pressure drop:

1.    • Normal value: 40mV (10A)

2.    Maximum value: 200mV (10A)

Minimum load: 1A 6VDC

Electrical life: 1*105 times

Mechanical life: 1*107 times, 300 times / min

Maximum continuous current:

1.    • NO contact: 30A (resistive)

2.    NC contact: 20A (resistive)

Insulation resistance: 100M Ω (500VDC)

Characteristic

☞    Contact switching capability 40A
☞    It has two contact forms: Normally Open(NO) and Changeover
☞    Operating temperature: 125°C
☞    Multiple operating voltages
☞    Comply with RoHS and ELV directives

Applications

Heater (seat, front/rear window heating control), fan control, wiper control, headlight control, car air conditioning, electromagnet control, lighting system, linkage, etc.

Introduction of common 4-pin or 5-pin Car Relays

m42

 Make & Break Relay

It is also known as SPST (Single-Pole, Single-Throw). There are 4 pins (or terminals) on the body with one high current circuit and contact. The contact is opened or closed depending on whether the relay is at rest or energized.

1.  ●  If the contact is closed when the relay is at rest, the relay is called Normally Closed (NC).

2.   If the contact opens when the relay is stationary, the relay is called Normally Open (NO). These relays are the more common type.

 Changeover Relay

It is also known as SPDT (single-pole, double-throw). There are 5 pins (or terminals) on the body, there are two contacts connected to a common terminal. The relays have two circuits, one is closed when the relay is at rest, and the other is closed when the relay is energized.

How to store relays?

  Avoid direct sunlight and maintain normal temperature, humidity, and pressure as below:

1.  ●  Temperature: 10 ℃ ~ 35 ℃

2.  ●  Humidity: 5 ~ 85% RH

3.  ●  Air pressure: 86 ~ 106kpa.

  Regularly check the products in stock and try to avoid the relay storage time being too long.

  The relay shall be stored and installed in a clean environment. Please use a dust cover or plastic encapsulated relay in the environment with dust pollution.